Multichannel Sampling Keys Accurate Power Line Monitoring
Accurate power-line monitoring has emerged as a critical requirement not only centrally within the power grid itself but also at its edges. For grid-tied energy-harvesting power-generation systems and even for end equipment, ongoing analysis of power quality characteristics helps ensure the health of the grid and attached systems. At the heart of power-monitoring systems, analog-digital converters (ADCs) play a key role in measuring line voltage and current at a level of accuracy appropriate to each application. Engineers can meet a range of requirements—from utility-grade systems with accuracy needed for revenue purposes to basic power monitors for detecting line faults—using high-performance ADCs and associated components from manufacturers including Analog Devices, Copal Electronics, Intersil, Linear Technology, Maxim Integrated, Microchip Technology, ON Semiconductor, Pulse Electronics, and Texas Instruments.
At the most basic level, power-monitoring systems rely on measurement of instantaneous current and voltage using current transformers (CTs) and voltage transformers (termed PT, for potential transformers) output converted by high-speed ADCs (Figure 1). In turn, a processor uses the instantaneous current and voltage measurements to calculate key characteristics including active power, reactive power, apparent power, and power factor—and even more complex calculations such as harmonics, which can result in equipment damage.
Figure 1: A typical power-monitoring system samples line current and voltage, using high-speed analog-digital converters (ADCs) to provide high-resolution data to the host processor for calculation of power parameters. (Courtesy of Texas Instruments)
Performing these power calculations depends foremost on accurately measured voltage and current. Standards such as ANSI C12.20 for North America and IEC 62053 dictate specific accuracy levels such as Class 0.2, which requires?± 0.2 percent accuracy. In practice, power-measurement systems are typically designed to surpass standard accuracy specifications—relying on high-sample rates and high-resolution converters to capture high-speed transients and to ensure reliable calculation of more complex characteristics such as multiple harmonics.
At the same time, measurement of these power characteristics requires tightly synchronized, high-resolution measurement of voltage and current across all three phases and neutral. Synchronized sampling allows extremely accurate measurement of phase angle between voltage and current on each line. Poor synchronization between voltage and current measurements can introduce artifacts, reduce overall accuracy, and significantly compromise more complex power calculations.
Simultaneous sampling
To reduce the complexity of high-accuracy multichannel measurement, designers can turn to highly integrated devices that combine high-resolution ADCs with analog front ends (AFEs) designed to optimize impedance matching, signal dynamic range, offset, and other factors that can erode performance and accuracy of data conversion. Manufacturers typically build these high-performance simultaneous sampling ADCs around successive-approximation register (SAR) converters. SAR ADCs offer high accuracy without the cycle latency associated with the oversampling used in delta-sigma ADCs to achieve high stability and conversion resolution.
For the most demanding applications, semiconductor manufacturers integrate a complex AFE and dedicated SAR ADC for each channel. For highly accurate power monitoring, eight-channel ADCs such as the Maxim Integrated MAX11046 and Texas Instruments ADS8568 allow simultaneous sampling of all three phases and neutral (Figure 2). With a dedicated AFE and ADC for each channel, these devices are able to achieve very high data rates—250 ksps per channel for the MAX11046 and 510 ksps for the ADS8568 (parallel-output interface).
Figure 2: For three-phase power monitoring, simultaneous sampling ADCs provide separate AFEs and ADCs for each of the eight channels required for highly accurate power calculations. (Courtesy of Maxim Integrated)
For some applications, designers can simply tie the unbuffered output of CTs and PTs directly into the inputs of ADCs including the Maxim Integrated MAX11046 and TI ADS8568 as suggested in Figure 2. Devices such as the MAX11046 provide high-input input impedance and self-protecting input clamps to support this type of simple configuration. To achieve maximum throughput, however, ADCs typically require op amp drivers between the transducers and ADC. In fact, evaluation boards from both Maxim Integrated and Texas Instruments include such drivers. On its MAXREFDES30 evaluation board for the MAX11046, Maxim Integrated includes its MAX44252 op amp drivers.? On the TI ADS8688EVM-PDK evaluation board for the ADS8568, Texas Instruments includes its OPA2209 op amp drivers.
Less-stringent requirements
For power monitoring applications with less stringent accuracy requirements, designers can turn to devices with more modest performance attributes. The simpler requirements in a power monitor that only needs to detect faults in the power line can take advantage of lower resolution ADCs. The Texas Instruments LMP92064 current/voltage monitor IC uses this approach to offer a single-line power-monitoring IC that requires few additional components (Figure 3). The device integrates a precision current sense amplifier to measure a load current across a shunt resistor and a buffered voltage channel to measure the voltage supply of the load. Nevertheless, the ability to sample current and voltage channels simultaneously by the independent 125-kSps, 12-bit ADCs supports accurate power calculations.
Figure 3: Power-monitor ICs such as the Texas Instruments LMP92064 use a pair of 12-bit ADCs to support power calculations for applications with less-demanding accuracy requirements. (Courtesy of Texas Instruments)
For even simpler monitoring requirements, designers can often use a single ADC with an external multiplexer to monitor voltage and current on each line. In fact, 8:1 multiplexers such as the Intersil DG408, Maxim Integrated MAX4581, and ON Semiconductor MC74HC4051A can support three-phase applications that require more basic power monitoring.
Designers can find ADCs with integrated multiplexers designed to support a broad range of channels, data throughput, and conversion resolution. For three-phase power monitoring, devices such as Analog Devices AD7699, Linear Technology LTC2372, and Texas Instruments ADS8688 integrate an eight-channel multiplexer with ADC and dedicated analog front end for each channel. For example, each input channel of the TI ADS8688 includes over-voltage protection, a programmable gain amplifier (PGA), low-pass filter, and driver feeding the shared multiplexer to the single ADC.
Conclusion
Ensuring grid power quality requires highly accurate measurement of voltage and current on each phase. For grid-tied energy-harvesting systems and equipment, power monitoring similarly requires high-resolution, simultaneous sampling of line voltage and current using ADCs providing a dedicated converter for each channel. Although basic fault monitoring builds on the same principles as high-accuracy measurement applications, designers can use lower-resolution ADCs or multiplexed devices that offer high-resolution multichannel measurement at lower throughput rates. Designers can find ready availability of ADCs designed to meet this broad range of requirements for channel support, bit resolution, and sample rate.
自動(dòng)翻譯僅供參考
多通道采樣精確的按鍵電力線監(jiān)控
準(zhǔn)確的電力線監(jiān)控已在電網(wǎng)本身,而且在其邊緣成為一個(gè)關(guān)鍵的要求,不僅集中。對(duì)于并網(wǎng)能量收集發(fā)電系統(tǒng),甚至為終端設(shè)備,持續(xù)的電能質(zhì)量特性分析,有助于確保電網(wǎng)和連接系統(tǒng)的健康狀況。在功率監(jiān)視系統(tǒng)的心臟,模擬 - 數(shù)字轉(zhuǎn)換器(ADC)起到測量線路電壓和電流的精度適合于每個(gè)應(yīng)用程序的電平的關(guān)鍵作用。工程師可以從制造商包括Analog Devices公司,產(chǎn)科寶電子,Intersil公司,凌力爾特滿足各種需求 - 從公用事業(yè)級(jí)系統(tǒng)精度所需收入的目的基本電源監(jiān)視器用于檢測線路故障,采用高性能ADC和相關(guān)組件, Maxim的集成,Microchip的科技,安森美半導(dǎo)體,電子脈沖和德州儀器。
在最基本的層面上,電力監(jiān)控系統(tǒng)依賴于瞬時(shí)電流和電壓使用電流互感器(CT)和電壓互感器的測量(稱為PT,用于電壓互感器)的輸出轉(zhuǎn)換成由高速ADC(圖1)。反過來,一個(gè)處理器使用的瞬時(shí)電流和電壓測量值來計(jì)算密鑰的特性,包括有功功率,無功功率,視在功率和功率因數(shù) - 甚至更復(fù)雜的計(jì)算,例如諧波,這會(huì)導(dǎo)致設(shè)備損壞。
德州儀器典型的電力監(jiān)控系統(tǒng)的圖像
圖1:典型的電力監(jiān)控系統(tǒng)的樣品線路電流和電壓,采用高速模擬 - 數(shù)字轉(zhuǎn)換器(ADC),提供高分辨率的數(shù)據(jù),以用于電力參數(shù)計(jì)算的主處理器。 (德州儀器提供)
執(zhí)行這些功率計(jì)算取決于最前面上精確地測量電壓和電流。如ANSI C12.20北美和IEC 62053標(biāo)準(zhǔn)規(guī)定的特定精度水平,如0.2級(jí),這需要±0.2%的精度。在實(shí)踐中,功率測量系統(tǒng)通常被設(shè)計(jì)為超越標(biāo)準(zhǔn)精度規(guī)格-依靠高采樣率和高分辨率的轉(zhuǎn)換器,以捕捉高速瞬變,并確保更復(fù)雜的特性,例如多諧波可靠的計(jì)算。
與此同時(shí),這些功率特性的測量需要緊密同步的,電壓和電流在所有三個(gè)階段和中性的高分辨率測量。同步采樣允許的電壓和電流,每行之間的相位角的非常精確的測量。電壓和電流測量之間缺乏同步可以引入假象,降低整體精度,顯著妥協(xié)更復(fù)雜的功率計(jì)算。
同時(shí)采樣
為了減少高精度多通道測量的復(fù)雜度,設(shè)計(jì)者可以轉(zhuǎn)向,結(jié)合高分辨率ADC與旨在優(yōu)化阻抗匹配模擬前端(AFE),信號(hào)的動(dòng)態(tài)范圍高度集成的器件,偏移,并且能夠侵蝕性能的其他因素和數(shù)據(jù)轉(zhuǎn)換的準(zhǔn)確性。制造商通常圍繞逐次逼近寄存器(SAR)轉(zhuǎn)換器這些高性能同步采樣ADC。 SAR ADC提供高精確度不與Δ-Σ模數(shù)轉(zhuǎn)換器用于實(shí)現(xiàn)高穩(wěn)定性和轉(zhuǎn)換分辨率的過采樣相關(guān)的周期延遲。
對(duì)于最苛刻的應(yīng)用,半導(dǎo)體制造商集成了復(fù)雜的AFE和專用SAR ADC,每個(gè)通道。對(duì)于高度精確的功率監(jiān)控,8通道ADC,例如Maxim的MAX11046集成和德州儀器ADS8568讓所有三個(gè)階段的同步采樣和中性(圖2)。為每個(gè)信道專用的AFE和ADC,這些設(shè)備都能夠?qū)崿F(xiàn)非常高的數(shù)據(jù)速率-250每個(gè)通道ksps的用于MAX11046和510 ksps時(shí)為ADS8568(并行輸出接口)。
Maxim的集成的三相電源監(jiān)控圖像
圖2:三相電源監(jiān)控,同時(shí)采樣ADC提供了獨(dú)立的AFE和ADC每個(gè)八通道需要高度精確的功率計(jì)算。 (馬克西姆集成提供)
對(duì)于一些應(yīng)用,設(shè)計(jì)人員可以簡單地扎CT和PT的緩沖輸出直接進(jìn)入的ADC包括的Maxim集成MAX11046和TI ADS8568的輸入,如圖建議2.設(shè)備如MAX11046提供高輸入的輸入阻抗和自我保護(hù)輸入鉗位支持這種類型的簡單配置。為了實(shí)現(xiàn)最大的吞吐量,但是,ADC通常所需要的換能器和ADC之間的運(yùn)算放大器的驅(qū)動(dòng)程序。事實(shí)上,無論從馬克西姆集成和德州儀器評(píng)估板包括這樣的驅(qū)動(dòng)程序。其MAXREFDES30評(píng)估板為MAX11046,美信集成包括其MAX44252運(yùn)算放大器的驅(qū)動(dòng)程序。在TI ADS8688EVM-PDK評(píng)估板為ADS8568,德州儀器包括其OPA2209運(yùn)放的驅(qū)動(dòng)程序。
不太嚴(yán)格的要求
對(duì)于電力監(jiān)控應(yīng)用不太嚴(yán)格精度要求,設(shè)計(jì)人員可以轉(zhuǎn)向更溫和的性能屬性的設(shè)備。較簡單的要求功率監(jiān)視器僅需要檢測故障在電力線可利用較低分辨率的ADC的優(yōu)勢。德州儀器LMP92064電流/電壓監(jiān)視IC使用這種方法來提供一個(gè)單線功率監(jiān)視IC,它需要很少的額外的組件(圖3)。該器件集成精密電流檢測放大器來測量分流電阻和一個(gè)緩沖電壓信道來測量電壓電源的負(fù)載的負(fù)載電流。盡管如此,由獨(dú)立125-ksps的同時(shí)采樣電流和電壓通道的能力,12位ADC支持精確的功率計(jì)算。
德州儀器LMP92064的圖
圖3:功率監(jiān)控器IC,例如德州儀器LMP92064使用一對(duì)12位ADC,支持功率計(jì)算與不太苛刻的精度要求的應(yīng)用。 (德州儀器提供)
對(duì)于更簡單的監(jiān)控要求,設(shè)計(jì)人員可以經(jīng)常使用單一的ADC,具有一個(gè)外部多路轉(zhuǎn)換器來監(jiān)視電壓和電流的每一行上。事實(shí)上,8:1多路復(fù)用器,如Intersil的DG408器,Maxim Integrated MAX4581和安森美半導(dǎo)體MC74HC4051A可以支持需要更基本的電力監(jiān)控三相應(yīng)用。
設(shè)計(jì)師可以找到的ADC設(shè)計(jì),支持廣泛的渠道整合多路復(fù)用器,數(shù)據(jù)吞吐量,并轉(zhuǎn)換分辨率。對(duì)于三相電源監(jiān)控,如ADI公司AD7699,凌特LTC2372和德州儀器ADS8688器件集成了八通道多路復(fù)用器與ADC和專用的模擬前端為每個(gè)通道。例如,TI的ADS8688的每個(gè)輸入通道包括過電壓保護(hù),可編程增益放大器(PGA),低通濾波器,并驅(qū)動(dòng)進(jìn)給共享多路復(fù)用到單個(gè)ADC。
結(jié)論
確保電網(wǎng)的電能質(zhì)量要求的電壓高精度測量和電流每相。對(duì)于網(wǎng)并列能量采集系統(tǒng)和設(shè)備,電力監(jiān)控同樣需要高分辨率,線電壓的同時(shí)采樣和當(dāng)前使用的ADC提供專用轉(zhuǎn)換器,用于每個(gè)信道。盡管基本的故障監(jiān)控建立在相同的原理,高精度測量應(yīng)用,設(shè)計(jì)人員可使用較低分辨率的ADC或提供高分辨率多通道測量以較低的吞吐速率復(fù)用的設(shè)備。設(shè)計(jì)師可以找到專為滿足這些廣泛的渠道支持,位分辨率和采樣率的ADC要求現(xiàn)成的可用性。